SPECIFICATION/MODEL | SKN-SS 1KW | SKN-SS 2KW | SKN-SS 3KW | SKN-SS 4KW | SKN-SS 5KW | SKN-SS 6KW |
DC Input | ||||||
Input Voltage(Vdc) | 12V/24V48V | 24V/48V | ||||
Min DC start voltage(Vdc) | 10V/20V40V | 20V/40V | ||||
AC Bypass | ||||||
Nominal Input Voltage | 110V or 230Vac(Waveform;Sine or generwtor) | 230Vac | ||||
Input AC Range (Vac) | 90Vac±4% or 184Vac±4%-253Vac±4% | 184Vac±4%-253Vac±4% | ||||
Frenquency Range(HZ) | 57HZ or 60 HZ (47 HZ-53HZ for 50HZ)......(57HZ-63HZ for 60HZ) | |||||
Input Frequency(Hz) | 50HZ/60HZ(Auto detection) | |||||
Bypass Output Voltage(Vac) | Same as input voltage | |||||
Bypass Output Frequency(HZ) | Sanme as input frequency | |||||
Pass through without Battery | Yes | |||||
Max Bypass Overload Current | 10A | 30A | 40A | |||
AC Efficiency | >95% | |||||
Transfer Time (ms) | 20ms(typical) | |||||
SOLAR CONTROLLER | ||||||
Solar Controller | 50A | 50A | 60A | |||
AMBIENT | ||||||
Noise(dB) | 60dB Max | |||||
Temperature | 0℃ to 40℃ | |||||
Humidity | 5% to 95% | |||||
Sea Level | ≤1500 | |||||
DIMENSION | ||||||
Products Size LxWxH(mm) | L488mm*W219mm*H304mm | L608mm*W219mm*H304mm | ||||
Packing size | L640mm*W312mm*H419mm | L760mm*W312mm*H419mm | ||||
AC CHARGER | ||||||
Charge mode Input Voltage Range | 95~127Vac or 90~265Vac | 90~265Vac | ||||
Automatic Charge mode | Three stage charge mode;Boost CC(constant current stage)→Boost CV(constant voltage stage)→Float(constant voltage stage) | |||||
Nominal Charge Voltage | According to the battery type setup | |||||
Charge Current(A) | Maximum 70A | |||||
Charge boost voltage(v) | According to the battrey type setup (12V BAT ;14-15.5V 24V BAT;28-31V 48V BAT;53.2-55.2 96V BAT;106.4-110.4V) | |||||
Charge Floating Voltage(V) | According to the battrey type setup (12V BAT ;13.3-13.7V 24V BAT;26.6-27.6V 48V BAT;53.2-55.2 96V BAT;106.4-110.4V) | |||||
Overcharge protection | BAT.V.>=15.7 Vdc,beeps0.5s every 1s& fault after 60S(15.7 for 12V,31.4V for 24V ,62.8 for 48V,125.6V for 96V) | |||||
Charge Short Circuit Protection | Circuit breaker | |||||
INVERTER | ||||||
Capacity(VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Output Power(W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Power Factor(PF) | 1 | |||||
Output Voltage | 120VAC or 230 VAC (Sine wave) | |||||
Output Ferquency | 50/60 ±0.3HZ(auto trackng main first power connection) | |||||
Wave | Pure sine wave | |||||
Inversion Efficiency | >88% | |||||
Overload Capacity | "(110% | |||||
Low Battery Alarm | 10.5Vdc±0.3Vdc for 12V battery,21.0Vdc for 24V battery,42.0Vdc±1.2Vdc for 48V battery,84.0Vdc±2.4Vdc for 96V battery | |||||
Power saver | Load<=25W(Enable on "P/S auto" setting of Remote control) |
Contact us if you need more details on Variable Frequency Inverter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Hybrid Solar Inverter、Suntech Inverters. If these products fail to match your need, please contact us and we would like to provide relevant information.